The following table outlines the configuration switch settings:
To ensure communications, leave Switch 2 in the FIXED BPS position and configure your communications software for 9600
baud.
When Switch 2 is in the PROGRAM position, the baud rate can be changed by entering or sending the escape and command
strings:
<ESC>HHP >100ms< 1s Bn
where n is the ASCII number corresponding to the baud rate shown in the table below.
For example, the string
<ESC>HHPB6 (which consists of the escape string and the command B6) would set the baud rate for
the network to 19200. No response will be transmitted back to the host after executing this function.
Note: You can also the HomeBase Configuration Utility program to alter the baud rate.
Creating a Dolphin 7200 HomeBase Network
This information applies only to the Dolphin 7200 HomeBase. The Dolphin 7200 Compact HomeBase is not networkable.
Each HomeBase must have its own AC power adapter connected to a standard AC electrical socket. The group can be placed
on a table or desk, or rail-mounted using the mounting holes on the two outside Dolphin HomeBase units.
How to Daisy Chain the Dolphin HomeBases
To form a HomeBase network, daisy chain the HomeBases together using one of the following methods:
Align adjacent units so that the MULTI-HOMEBASE PORT of one unit will mate with the MAIN COMM PORT of the next unit
until all HomeBases in the network are connected.
Use a RS-232 cable to connect the Multi-HomeBase Port on one terminal to the MAIN COMM PORT on the next terminal.
Repeat this step to include each additional terminal in the chain. Connect the last terminal to the host computer and leave the
last MULTI-HOMEBASE PORT open if it is not needed.
Programming Commands
To configure a Dolphin HomeBase network, these attributes must be programmed:
1. Address Assignment,
Switch Setting Function
1 SINGLE (UP) Single HomeBase only
2 FIXED BPS (DOWN) Baud rate fixed at 9600
2 PROGRAM (UP) Baud rate can be programmed
Baud Rate per Value of n
ASCII Value of “n” Selected Baud Rate ASCII Value of “n” Selected Baud Rate
0 38400 6 19200
1 38400 7 38400
2 1200 8 57600
3 2400 9 115200